Technical Committee No |
TC04 |
|
Status |
Active |
|
Category |
Metrology Sector |
|
Sub Category |
|
|
$Resources:StandardType; |
Kuwaiti Standard |
This International Standard specifies a charcoal
tube/gas chromatographic method for the determination
of the concentration of vaporous aromatic
hydrocarbons in workplace air.
The method is valid for the measurement of the
concentrations of airborne vapours of any of the following
compounds:
a) benzene;
b) toluene;
c) ethylbenzene;
d) m-xylene;
e) o-xylene;
f) p-xylene;
g) styrene (vinylbenzene);
h) cumene (isopropylbenzene);
i) 1,2,3-trimethylbenzene;
j) 1,2,4-trimethylbenzene;
k) 1,3,5-trimethylbenzene;
I) 4-terf-butyltoluene;
m) 3-methylstyrene;
n) 4-methylstyrene;
o) isopropenylbenzene.
The method is valid for concentrations of airborne
vapours of these compounds in the range from approximately
1 mg/m3 to 1000 mg/m3 (about
0,2 ml/m3 to 200 mVm3; see 8.1) when sampling
10 litres of air.
NOTE 1 The upper limit of the useful range is set by the
adsorptive capacity of the first section of the charcoal
tube (5.1) used. This capacity is measured as a breakthrough
volume of air, which should not be exceeded
during sampling (see clause 6 and annex A).
The lower limit is set by a number of parameters, including
the noise level of the detector (5.9) blank concentrations
due to the contamination of the charcoal and
carbon disulfide by the substance analysed, desorption
efficiency (see annex B) and interference of the solvent
peak in the gas chromatographic analysis.
The method is also valid for the measurement of
airborne concentrations of mixtures of these compounds.
In such cases, the unique properties of each
compound have to be considered when determining
the volume of air to be sampled and the gas chromatographic
conditions to be used. The method may
be applicable for other substituted monocyclic
aromatic hydrocarbons, but its validity has to be
tested.
NOTE 2 When analysing aromatic hydrocarbon mixtures
with very large differences in concentrations and in
which several compounds are present, the reproducibility
and repeatability of the compounds of minor importance
might be influenced.
The method has been validated for a selection of
typical aromatic hydrocarbons[ll.
This procedure is compatible with low flow rate
personal sampling equipment, and can be used for
personal and fixed location sampling for obtaining
time-weighted-average concentrations of aromatic
hydrocarbon solvent vapours in air. It cannot be
used to measure instantaneous or short-term fluctuations
in concentrations. Alternative on-site pro-
|
|
|
|
Decision No |
94/2013 |
|
|
Decision By |
From Ministers Office |
|
|
Date of Meeting |
13-08-2025 |
|
|
Approval Date |
|
|
|
Decision Date |
31-03-2013 |
|
|
Newspaper Publication Date |
|
|
|
Newspaper Number |
|
|