Technical Committee No TC01
Status Active
Category Chemical And Textile Sector
Sub Category

This International Standard specifies a complete set of values of Performance characteristics for automated measuring Systems for the continuous measurement of the mass concentrations of Sulfur dioxide in stationary Source emissions. NOTE 1 If the Performance characteristics of an automated measuring System are listed according to table 1, this ensures that the automated measuring System is reliable and gives satisfactory continuous results. The set of data listed in table 1 refers to the performante characteristics of measurement methods, including all Steps from sampling to recording and, if necessary, storage of data. This International Standard is applicable to extractive and non-extractive automated Sulfur dioxide measuring methods. For both methods it implies the applicability of Zero and calibration gas and the availability of comparable samples. The automated measuring System tan be calibrated with calibration gases, by applying the manual method described in ISO 7934, or by applying an automated measuring System previously verified according to this International Standard using a different principle of detection. The value of the integral Performance (3.7) is determined by using ISO 7934 or an automated measuring System verified according to this International Standard with a different principle of detection. At present, the range over which this specification applies is between 0 g/m3 to 0,l g/m3 and 0 g/m3 to 8 g/m3 (see table 2 for details).

Files

pdf
English

11 Pages

KWD 25.600