This International Standard specifies a method for the direct determination of water in petroleum products boiling
below 390 °C. It covers the mass fraction range 0,003 % (m/m) to 0,100 % (m/m).
This International Standard may be applicable to petroleum products boiling above 390 °C and lubricating base oils.
However, the precision has not been established for these materials.
NOTE 1 A number of substances and classes of compounds associated with condensation or oxidation-reduction reactions
interfere in the determination of water by Karl Fischer titration. In petroleum products, the most common interferences are
hydrogen sulfide and mercaptan sulfur, however, concentrations of these below 0,003 % (m/m) as sulfur will not cause
significant interference over the range 0,003 % (m/m) to 0,100 % (m/m) water. Other organic sulfur compounds commonly
present such as sulfides, disulfides and thiophenes, do not interfere.
NOTE 2 For the purposes of this International Standard, the terms “% (m/m)” and “% (V/V)” are used to represent the mass
and volume fractions of a material respectively.
|
|
|
|