​​​​​

Technical Committee No TC07
Status Active
Category Oil and Gas Sector
Sub Category

This International Standard specifies a method for the determination of the ability of paints (including waterborne paints), varnishes, paint binders, adhesives, solvents and petroleum and related products, when maintained at a selected test temperature within the range of ? 30 °C to 300 °C, and under the conditions of test, to yield sufficient flammable vapour at this temperature to cause ignition on the application of a test flame in a standard manner. When used in conjunction with the flash detector (A.1.6), this International Standard is also suitable to carry out a flash/no flash test on fatty acid methyl esters (FAME).

Files

pdf
English

24 Pages

KWD 51.500