1.1 This practice covers a technique for using heat flux
transducers (HFTs) and temperature transducers (TTs) in measurements of the in-situ dynamic or steady-state thermal
behavior of opaque components of building envelopes. The
applications for such data include determination of thermal
resistances or of thermal time constants. However, such uses
are beyond the scope of this practice (for information on
determining thermal resistances, see Practice C1155).
1.2 Use infrared thermography with this technique to locate
appropriate sites for HFTs and TTs (hereafter called sensors),
unless subsurface conditions are known.
1.3 The values stated in SI units are to be regarded as the
standard. The values given in parentheses are for information
only.
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
|
|
|
|
Decision No |
3/2023 |
|
|
Decision By |
From Ministers Office |
|
|
Date of Meeting |
18-12-2022 |
|
|
Approval Date |
|
|
|
Decision Date |
08-02-2023 |
|
|
Newspaper Publication Date |
02-04-2023 |
|
|
Newspaper Number |
1629 |
|