1.1 This guide describes methods for determining and
evaluating causes of water leakage of exterior walls. For this
purpose, water penetration is considered leakage, and therefore
problematic, if it exceeds the planned resistance or temporary
retention and drainage capacity of the wall, is causing or is
likely to cause premature deterioration of a building or its
contents, or is adversely affecting the performance of other
components. A wall is considered a system including its
exterior and interior finishes, fenestration, structural components,
and components for maintaining the building interior
environment.
1.2 Investigative techniques discussed may be intrusive,
disruptive, or destructive. It is the responsibility of the investigator
to establish the limitations of use, to anticipate and
advise of the destructive nature of some procedures, and to
plan for patching and selective reconstruction as necessary.
1.3 This practice does not purport to address all of the
safety concerns, if any, associated with its use. Establish
appropriate safety and health practices and determine the
applicability of regulatory limitations prior to use. Awareness
of safety and familiarity with safe procedures are particularly
important for above-ground operations on the exterior of a
building and destructive investigative procedures which typically
are associated with the work described in this guide.
|
|
|
|