Technical Committee No TC06
Status Replaced
Category Construction and Building Sector
Sub Category

1.1 This specification establishes the requirements for welded copper tube with a longitudinal seam free of filler metal produced from sheet or strip of the following coppers: Copper UNS Nos. Type of Copper C10100 Oxygen-free electronic C10200 Oxygen-free C10300 Oxygen-free, extra low phosphorus C10800 Oxygen-free, low phosphorus C11000 Electrolytic tough pitch C12000 Phosphorus deoxidized, low residual phosphorus C12200 Phosphorus deoxidized, high residual phosphorus C14200 Phosphorus deoxidized, arsenical 1.2 Unless otherwise specified in the contract or purchase order, product furnished of any listed copper, with the exception of copper C11000, shall be considered acceptable. 1.2.1 Copper C11000 welded tube shall not be used in applications where hydrogen embrittlement during heating is a concern. 1.3 Values stated in inch-pound units are the standard except for grain size, which is given in SI units. Values given in parentheses are for information only. 1.4 The following hazard caveat pertains only to Section 13 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Files

pdf
English

9 Pages

KWD 26.420