1.1 This specification covers the performance of nonasbestos,
fiber-reinforced cement shake, shingle, and slate
roofing systems that are of uniform or nonuniform thickness
and texture.
1.2 This specification does not include details of product
installation and workmanship. The manufacturer’s installation
instructions shall be referred to for details such as slope,
interlayment, underlayment, sheathing requirements, exposure,
fasteners, and repair or replacement instructions.
1.3 This specification does not address requirements for
individual shake, shingle, and slate products, which are covered
in Specification C1225 and C1530.
1.4 The tests contained in this specification are intended as
qualification tests for a roofing system. Changes in product
formulation, design, or manufacturing process beyond the
ranges allowed in the manufacturer’s quality control specifications,
shall require subsequent system retesting or written
concurrence by an independent testing agency that the changes
in formulation, design, or manufacturing process will not be
detrimental to system performance.
1.5 The values stated in inch-pound units are to be regarded
as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only
and are not considered standard.
1.6 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appropriate
safety and health practices and determine the applicability
of regulatory limitations prior to use.
|
|
|
|